Gas Analyser It uses in measuring automotive emission exhaust CO, HC, CO2, O2, (NOX). LCD display with Chinese/English operation menu. It is easy to operate. Inside bench is world advanced bench that meets OIML class 0 made by HORIBA Japan. The other sensors are import world brand products. Opacimeter With functions of free acceleration test and measurement of transients, automatic process of test data and display of measuring results meets the requirements of ISO11614 and GB3847-1999
Features Smoke
- Split structure, separated measuring unit and control unit for easy operation.
- Large LCD screen, English interactive menu, with opacity reading and light absorption coefficient reading, simple, direct and convenient operation.
- With functions of free acceleration test and measurement of transients, automatic process of test data and display of measuring results
- 15 minutes less than for warm-up time, automatic zero reset.
- With adoption of advanced partial flow technology, measuring unit tests smoke emissions of diesel-powered vehicles directly. “Scavenge air curtain” technology prevents the optical system from being polluted. With constant temperature control in the sample cell, it can avoid condensation and influence of accuracy due to change of temperature.
- With functions of data printing and communication with host computer. Serial RS-232C interface or RS-485C interface can be selected.
- The performance meets the requirements of ISO11614 and GB3847-1999.
- RS-232 port serial
- To be connected to an external PC which allow to integreated C-NET (Cosber Network)
Features Gas
- It uses in measuring automotive emission exhaust CO, HC, CO2, O2, (NOx optional)
- LCD display with English operation menu. It is easy to operate
- Meets the international standard ISO 3930 or OIML R99 NDIR gas sensor, HORIBA bench Level 1 accuracy requirements
- It has the functions with auto zero, auto calibration and leak check
- Flexible probe can suit almost all kinds tail tube
- It is equipped with the newest aluminum alloy drain separator. So that the efficiency of water separation is better
- Auto compensation ambient pressure and environmental temperature for eliminating variable influence
- Auto calculate engine AFR, Lamda
- It is equipped two idle test tufunction
- Input data vehicle
- RS-232 port serial
- To be connected to an external PC which allow to integreated C-NET (Cosber Network)
Specification
Technical Data
No | Desciption | GAS KWQ | OPA KYD |
---|---|---|---|
1 | Measurement | CO, CO2, HC, O2, NOx (option) | Opacity N% / Koefisient |
2 | Resolution | ±0.02% | 0.01m¹ |
3 | Range | HC: 0-10000ppm vol
CO: 0-15.00%vol CO2: 0-18.00%vol O2: 0-25.00%vol NO: 0-5000ppm vol Lamda: 0.5 - 3.0 |
K-16m¹
N: 0 - 100% |
4 | Output Interface | Yes RS-232 | Yes RS-232 |
5 | Warm-Up Time | 30 seconds | less than 15 minutes |
6 | Power Supply | AC 100-220V 50/60Hz | AC 100-220V 50/60Hz |